Setup Digitizer wizard |
|
Automatic Detection |
< Back | Next > |
This page helps you to check:
If the communication between digitizer and computer port is correct, you will assign the digitizer cursor buttons with the Automatic Setup.
Received digitizer coordinates (check whether you have communication):
Do not press any buttons on the digitizer cursor. Move your digitizer cursor over the tablet. Inspect the string that is listed on the first line after 'Received'.
You have communication between the digitizer and the computer:
Received: coordinates as readable numbers
The message Trying Automatic Detection will appear.
The digitizer setup is proceeding satisfactorily: you can continue to have ILWIS recognize the digitizer cursor buttons. Follow the instructions for Automatic Detection (below).
You definitely don't have communication between your digitizer and your computer:
Received: Nothing
Received: coordinates as unreadable characters
Go to the Trouble shooting section (below).
Trying Automatic Detection:
When you have communication and when the message Press Button 0 appears:
You will automatically go to the last page of the Setup Digitizer wizard: the Setup Digitizer - Size, Resolution, Final Check page.
If you experience any strange behaviour when using Automatic Detection, you may go Back to the Port Settings page and then with Next to this Automatic Detection page and try again. Otherwise go to the Trouble shooting section (below).
Trouble shooting:
Received: Nothing
Problems: You may have selected the wrong Port number; the Port Settings (such as Baud Rate, Data Bits, etc.) may not correspond to the digitizer configuration settings; the digitizer may not send coordinates in ASCII format; the digitizer may not be configured to work in Run Mode.
Received: coordinates appear as unreadable characters
Problem: Digitizer may not send coordinates in ASCII format.
Problem: Digitizer may not be configured to work in Run Mode.
Problem: Digitizer may not be configured to work in Run Mode and/or reduce the Data Rate.
Problem: Digitizer is not configured to work in Run Mode.
Port Settings may be already correct.
Try going Back to the Port Settings page and then with Next to this Automatic Detection page and try again.
If this does not solve your problem: check all digitizer settings.
Remedy:
Tip:
It is strongly advised to first ensure the communication between the digitizer and the port and then to choose the ILWIS Automatic Detection. Trying the manual setup button on this page will not make things easier.
Manual setup (advanced):
Press the Manual button if you are sure that you have communication, but when Automatic Detection is not able to recognize a certain 'difficult' digitizer Format. You can unravel the received ASCII string yourself: the Setup Digitizer - Manual Setup page will appear.
See also: